
Add to Cart
DIN EN 60228 Class 5 Rubber Insulated Cable For Industrial And Agricultural
Application:
For general use in dry locations for connections of electrical apparatus submitted to weak mechanical strength, like vacuum cleaner, kitchen appliance, etc. unsuitable for industrial and agricultural use.
Construction:
1 ..... fine-stranded bare copper
2 ..... core insulation of rubber
3 ..... outer sheath of ordinary ethylene propylene rubber, black
Standards:
DIN VDE 0282-4
DIN EN 60228 class 5 (construction)
HD 308 S2 (core identification)
HD 22.4 S4:2004
Technical data:
Nominal voltage Uo/U | [V] | 300 / 500 volt | |
Test voltage | [V]AC | 2000 | |
Temperature range | in motion | -25°C till +60°C | |
Operating temperature | short circuit | °C | 200 |
Short circuit time | max. | [sec] | 5 |
Bending radius | one time / fixed | x diameter | 4 |
in motion | x diameter | 8 | |
Flammability | standard | EN 60332-1-2 |
Number of cores and nominal cross section mm2 |
Copper figure kg/km |
Cond. construction (appr. value) mm |
Overall diameter appr. mm |
Weight appr. kg/km |
|||
---|---|---|---|---|---|---|---|
2 X 0,75 | 15,0 | 24 x 0,21 | 6,2 | 56 | |||
3 G 0,75 | 22,5 | 24 x 0,21 | 6,7 | 72 | |||
4 G 0,75 | 30,0 | 24 x 0,21 | 7,3 | 86 | |||
5 G 0,75 | 37,5 | 24 x 0,21 | 8,2 | 109 | |||
2 X 1 | 20,0 | 32 x 0,21 | 6,8 | 68 | |||
3 G 1 | 30,0 | 32 x 0,21 | 7,2 | 82 | |||
4 G 1 | 40,0 | 32 x 0,21 | 7,8 | 98 | |||
2 X 1,5 | 30,0 | 30 x 0,26 | 8,2 | 101 | |||
3 G 1,5 | 45,0 | 30 x 0,26 | 8,8 | 120 | |||
4 G 1,5 | 60,0 | 30 x 0,26 | 9,8 | 155 | |||
5 G 1,5 | 75,0 | 30 x 0,26 | 10,7 | 185 | |||
2 X 2,5 | 50,0 | 50 x 0,26 | 9,7 | 145 | |||
3 G 2,5 | 75,0 | 50 x 0,26 | 10,2 | 180 | |||
4 G 2,5 | 100,0 | 50 x 0,26 | 11,2 | 225 | |||
5 G 2,5 | 125,0 | 50 x 0,26 | 12,7 | 282 |