FRNC Communication Solid Copper Telephone Cable Flame Retardant Non Corrosive
Application:
Low-smoke. zero-halogen communication cable with improved flame-retardance. Primarily for use in buildings with a high concentration of people or material assets. For the connection of communication units indoors in wet and dry rooms on and under plaster. For outdoor installation the cable must be protected from sunlight
Construction:
Class 1 Solid Tinned Bare Copper
Insulation
Flame Retardant Non-Corrosive compound HI1
Screen
Plastic Coated Aluminium Foil
Drain Wire
Solid Copper
Sheath
Flame Retardant Non-Corrosive compound HM1
Standards:
VDE 0815.
Flame Retardant: VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke Density: DIN EN 61034/IEC 61034
Halogen Free: DIN EN 50267/IEC 60754
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of
Hazardous Substances) is determined and confirmed.
CHARACTERISTICS
Operating Voltage
300V
Temperature Rating
Fixed: -30°C to +70°C
Minimum Bending Radius
Fixed: 7.5 x overall diameter
Core Identi ication4 cores twisted into star quads
Star quads: Red Green Grey Yellow White
One star quad marked by rings
Wire 1: without ring
Wire 1: one ring. wide spaced
Wire 2: Double ring. wide spaced
Wire 2: Double ring. narrow spaced
Sheath Colour
Grey